    • Maheshwari, G. P.; Mulla Ali, A. A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      The weather in Kuwait is very dry where the dry-bulb temperature exceeds the wet-bulb temperature more than 20oC in most of the summer months. Thus, the air-conditioning (A/C) system with the water-cooled (WC) condensers ...
    • Al-Bassam, E.; Maheshwari, G. P.; Sebzali, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Air-conditioning (A/C) in Kuwait is a necessity for comfortable living as the summer is extremely hot. Dry weather for most of the summer months reflects the effectiveness of using water-cooled (WC) systems. Cooling towers ...
    • Al-Taqi, H. H.; Maheshwari, G. P.; Alasseri, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      For the existing housing, retrofitting single or double glazed clear glass window with solar films can be an effective measure to reduce their peak power demand, and large scale application of the same on national level ...
    • ElSherbini, A.; Maheshwari, G. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      In air-conditioning (A/C) systems with air-cooled condensers, the condensing unit has to be kept in the open for easy access to outdoor air in order to efficiently dissipate heat. During daytime, the solar radiation falling ...
    • Al-Mulla, A.; Maheshwari, G. P.; Al-Nakib, D.; Ishaqali, H. (Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
      The smart operation strategies were implemented for Air-Conditioning (A/C) and lighting systems to reduce the national load at Ministries Complex (MC) in the state of Kuwait. The A/C system in MC is a district cooling ...
    • Shaban, N.; Maheshwari, G. P.; Suri, R. K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Design conditions based on the meteorological data collected at two weather stations located less than 10 km away from each other within Kuwait City are presented for dry-bulb temperature (DBT) and web-bulb temperature ...
    • Ali, A. A.; Maheshwari, G. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007)
      A model co-relating the peak load demand of a utility with the allowable power rating (PR) of air-conditioning (AC) systems has been developed in this paper through a well defined methodology. The model is capable to ...
    • Al-Mulla, A.; Maheshwari, G. P.; Al-Nakib, D.; ElSherbini, A.; Alghimlas, F.; Al-Taqi, H.; Al-Hadban, Y. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
      An innovative approach was developed and implemented in eight governmental buildings to reduce their load during the peak demand hours in summer of 2007. The innovative approach implemented in these buildings included ...
    • Maheshwari, G. P.; Hajiah, A. E.; ElSherbini, A. I. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007)
      This paper analyzes the impact of chilled water flow and its distribution on energy efficiency and comfort quality, using the results of a field study conducted for a central cooling production system during 2006 in Kuwait. ...
    • Al-Nakib, D.; Al-Mulla, A. A.; Maheshwari, G. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      Lighting systems are the second major contributor to the peak power demand and energy consumption in buildings after A/C systems. They account for nearly 20% of the peak power demand and 15% of the annual energy consumption. ...
    • Al-Hadban, Y.; Maheshwari, G. P.; Al-Nakib, D.; Al-Mulla, A.; Alasseri, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      This paper presents the achievements of implementing smart operations strategies for air-conditioning (A/C) and lighting systems in Justice Palace Complex (JPC), Kuwait during the summer 2007. The peak load of this building ...
    • Al-Hadban, Y.; Maheshwari, G. P.; Al-Nakib, D.; Al-Mulla, A.; Alasseri, R. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
      During the summer 2007 smart operation strategies for air-conditioning (A/C) and lighting systems were developed and tested in a number of governmental buildings in Kuwait as one of the solutions to reduce the national ...
    • Hajiah, A. E.; Maheshwari, G. P.; ElSherbini, A. I. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
      In medium and large size air-conditioning (A/C) systems maintaining a logbook that has hourly data on operation of chillers and pumps is mandatory. The paper presents a methodology for establishing performance of a chilled ...